Button for 1977 Button for 1984 Button for 1990 Button for 1995 Button for MDC Button for notes Button for examples

GKS - /GQDVL

1995 Version of ANSI (Equivalent to Current ISO Version) of Standard

4.19.26 GQDVL, Inquire default valuator device data

control-
mnemonic
  Level   GKS function name
GQDVL mb Inquire default valuator device data
2 parameters
p1 ::= gksnam workstation type
p2 ::= gksint logical input device number (1..n)
Right Arrow Write /GQDVL("WORK1",1)
6 values returned
v1 ::= gksint error indicator
v2 ::= gksnum default initial value
v3 ::= gksint number of available prompt and echo types (1..n)
v4 ::= M gksint n value list of available prompt and echo types (-n..–1,1..n)
v5 ::= L gksnum 4 value default echo area (DC)
v6 ::= gksdat default valuator data record
Left Arrow Read Error,Value,NumPrmp F ii=1:1:NumPrmp R Prompt(ii)
Left Arrow Read EchoArea,ValueDat