GKS - /GQLPF

1995 Version of ANSI (Equivalent to Current ISO Version) of Standard

4.19.6 GQPLF, Inquire polyline facilities

control-
mnemonic
  Level   GKS function name
GQPLF ma Inquire polyline facilities
1 parameter
p1 ::= gksnam workstation type
Right Arrow Write /GQPLF("WORK1")
8 values returned
v1 ::= gksint error indicator
v2 ::= gksint number of available linetypes (4..n)
v3 ::= M gksint n available linetypes (-n..–1,1..n)
v4 ::= gksint number of available linewidths (0..n)
v5 ::= gksnum nominal linewidth (DC)
v6 ::= gksnum minimum linewidth (DC)
v7 ::= gksnum maximum linewidth (DC)
v8 ::= gksint number of predefined polyline indices (0,5..n)
Left Arrow Read Error,Num F ii=1:1:Num R LineType(ii)
Left Arrow Read WidNum,WidNom,WidMin,WidMax,Lineindx