GKS - /GQWKT

1995 Version of ANSI (Equivalent to Current ISO Version) of Standard

4.18.17 GQWKT, Inquire workstation transformation

control-
mnemonic
  Level   GKS function name
GQWKT ma Inquire workstation transformation
1 parameter
p1 ::= gksnam workstation ID
Right Arrow Write /GQWKT("WORK1")
6 values returned
v1 ::= gksint error indicator
v2 ::= gksenum workstation transformation update state:

NOTPENDING
PENDING

v3 ::= L gksnum 4 value requested workstation window (NDC)
v4 ::= L gksnum 4 value current workstation window (NDC)
v5 ::= L gksnum 4 value requested workstation viewport (DC)
v6 ::= L gksnum 4 value current workstation viewport (DC)
Left Arrow Read Error,State,ReqWind,CurWind,ReqView,CurView