☜ | GKS - /GINLC1995 Version of ANSI (Equivalent to Current ISO Version) of Standard | ☞ |
control- mnemonic |
Level | GKS function name |
---|---|---|
GINLC | mb | Initialize locator |
7 parameters | ||
p1 ::= gksnam | workstation ID | |
p2 ::= gksint | locator device number (1..n) | |
p3 ::= gksint | initial normalization transform number (0..n) | |
p4 ::= gkspnt | initial locator position (WC) | |
p5 ::= gksint | prompt and echo type (-n..–1,1..n) | |
p6 ::= L gksnum | 4 values defining echo area (Xmin, Xmax, Ymin, Ymax) (DC) | |
p7 ::= gksdat | locator data record | |
Write /GINLC("WORK1",100,3,"1,1",1,"1,0,1,0","LOCATOR DATA") |
Copyright © Standard Documents; 1977-2024 MUMPS Development Committee;
Copyright © Examples: 1995-2024 Ed de Moel;
Copyright © Annotations: 2003-2008 Jacquard Systems Research
Copyright © Annotations: 2008-2024 Ed de Moel.
This page most recently updated on 13-Sep-2014, 14:03:07.
For comments, contact Ed de Moel (demoel@jacquardsystems.com)